”. Pressing the button will turn on or off the LCD
backlight. The backlight will turn off automatically
after.
(4) “SAVE/READ” Button
The read data function works in conjunction with the
save function in the shift mode, it is used for reading
save
d data. The save function can be activated in shift
mode
. Press the SAVE/READ button to read saved
data
; the word “READ” should be displayed on the
LCD
. To navigate around the save data table, press the
overla
y SECOND button until the “# sign is dis-
playe
d on the second display. The location of the read
pointe
r within the saved data table will be displayed.
Th
e arrow buttons on the overlay are used for scrolling
throug
h the saved data. Press the smaller arrows
or “ ” to step through the data one at a time. Press the
large
r arrows or to step through the data
te
n at a time. Pressing the overlay “ESC” button deac-
tivates the read data function.
(5) “LOG/READ” Button
The read log function works in conjunction with the log
function
. It is used for reading logged data. The log
functio
n can be activated in the shift mode. Press the
LOG/REA
D button to activate the log read function;
th
e word READ” is displayed on the LCD. Press the
overla
y SECOND button to rotate through following
displa
y menus: T1, T2, GRP, and #. T1 and T2: Dis-
play
s the T1 or T2 saved data. GRP: Displays the cur-
ren
t group number. #: Displays the current location of
th
e read pointer within a selected group. The arrow
button
s on the overlay are used for scrolling through
th
e data and groups. Press the smaller arrows or
to step through the logged data or groups one at a
time
. Press the larger arrows
or to step
throug
h the data or groups ten at a time. To navigate
th
e logged data and groups, press the overlay
SECON
D button until GRP appears in the second dis-
pla
y panel. Then select the group using the arrows.
Pres
s the SECOND button again until the “#” sign is
displayed
. The location of the read pointer in the se-
lected group will be displayed. Use the arrows to
scrol
l through the data. Pressing the overlay “ESC
button deactivates the read data function
(7) HOLD Mode (only Main display)
When HOLD mode is selected, the thermometer holds
th
e present readings and stops all further measure-
ments
. To activate the data hold mode, press the
HOL
D button, and “HOLD” is displayed on the LCD.
Pressin
g the HOLD button again cancels the function,
an
d the instrument will automatically resume meas-
urements.
(8) MIN/MAX with time record Mode
(only Main display)
The MIN/MAX function records the highest and low-
es
t value recorded, and it calculates the average read-
ing
, and the differences of MAX to MIN. Press
MIN/MA
X button to enter the MIN/MAX recording
mode
. The beeper emits a tone when a new minimum
or maximum measurement is recorded. Press the
MIN/MA
X button again to rotate through the current
readings
: MAX: The highest measurement recorded.
MIN
: The lowest measurement recorded. MAX-MIN:
Th
e difference of the highest and the lowest measure-
ment. AVG: The average values of the measurements.
Thi
s mode works in conjunction with the hold func-
tion
, pressing the HOLD button will stop the recording
an
d measurements (Previously recorded readings are
no
t erased). Press HOLD button again to resume re-
cordin
g and measurements. To prevent accidental loss
of MIN, MAX and AVG data, the MIN/MAX function
ca
n only be cancelled by pressing and holding down
th
e MIN MAX key for more then 2 seconds. The
automati
c power-off feature, and the power, °C/°F,
REL
, SET, Hi/Lo Limits, TYPE, T1/T2 buttons are
also disabled.
(10) “T1/T2” Button (Main display)
The input selection button [T1/T2] selects the input for
th
e main display, T1 thermocouple or T2 thermocou-
ple
. Press the T1/T2 button to switch between the two
inputs
. When meter is turned on, it is set to the display
that was last in use.
(11) “T1/T2” Button (Second display)
The input selection button [T1/T2] selects the input for
th
e second display, T1 thermocouple or T2 thermo-
couple
. Press the T1/T2 button to switch between the
tw
o inputs. When meter is turned on, it is set to the
display that was last in use.
(12) “T1-T2/TIME” Button (Third display)
The input selection button [T1-T2] selects the system
tim
e and date, or the differential between the two
thermocouple
s (T1-T2) for the third display. Press the
T1-T
2 button to switch the display options. When
mete
r is turned on, it is set to the display that was last
in use.
3. SHIFT MODE
The following functions can only be used in the shift
mode.
(2) “°C/°F” Button
Press the °C/°F button to select the temperature
reading
s can be displayed in Celsius C) or Fahre
hei
t (°F). When the thermometer is turned on, it
to the temperature scale that was last in use.
(4) “SAVE” Button
The save function stores the T1, T2 data in a nonvola
til
e memory. Press the SAVE button to save the
ren
t data, the word SAVE is displayed to indicate
dat
a has been saved. The built in memory can store
to 256 data. The data can be read using the read
tion in the normal mode.
(5) “LOG” Button
The data log function continuously records the
accordin
g to a specified time interval. The time
va
l can be set using the interval setup function [INVT]
in the set up mode. Press the LOG button to activate
th
e log function; the indicators “LOG and “MEM”
wil
l be displayed on the LCD. There are 16 groups
ar
e used for storing the log data. A maximum
16,00
0 data points can be saved in one log session.
Pres
s the LOG button again to exit the data log
tion.
(6) “CLR ?” Button
The CLR function clears all the saved and logged
in memory. When the CLR button is pressed, indicator
“MEM
is displayed and the “CLR” on upper-right
LC
D will blink. Pressing the ENTER” button printed
on the overlay in white will clear all saved and logged
data
. Press “ESC” button to exit this function without
clearing data.
(7) “REL” Button (Main display)
The relative value function can be used for comparing
a saved reference value with other measurements.
Pres
s the REL button to store the current measur
men
t as the reference value, and “REL” should be
playe
d on the right part of the LCD. The next
uremen
t will display the current value compared
referenc
e value. Press REL” button again to clear
referenc
e value and deactivate the relative value
urement function.
(8) “APO” Button
Press the APO button to turn the Auto power
functio
n on or off. When this function is enabled,
indicato
r “APO” is shown at the upper left part
LCD
. When APO (Auto power off) is enabled, it
automaticall
y turn the thermometer off no button
presse
d for a period longer than the set time inte
(th
e default time for APO is 5 minutes). Press power
button to resume operation.
(10) “TYPE” Button (Main display)
Press this button to change the type of thermocouple
th
e main display (K/J/T/E/R/S/N). If the inputs
mai
n and second display are the same, then pressing
thi
s button will change the thermocouple type for
displays.
(11) “TYPE” Button (Second display)
Press this button to change the type of thermocouple